CONTROLS
Following one or more modes of controls are provided:
Manual Mode
a) Tap switch control method.
The DC output voltage of the TRU in this mode
is controlled in 24 symmetrical steps by means
of a separate autotransformer
with coarse & fine tapping. Autotransformer
can have steps of 16, 24 or 64 as per customer
specification.
b) Stepless autotransformer method.
The DC output voltage of the TRU in this mode
is controlled by stepless separate autotransformer
connected in primary of
main transformer.
Constant Voltage Constant Current Mode
In this mode the unit can be operated in either
constant voltage or constant current mode. In
constant voltage mode the DC output voltage will
be adjustable from 0 to rated value in stepless
manner by means of a voltage setter potentiometer.
DC Voltage regulation will be better than 0.5%.
The controller will maintain constant voltage
at set value under input supply variation and
load current variation to keep the structure protected.
In constant current mode the DC output current
will be adjustable from 0 to rated value in stepless
manner by means of a current setter potentiometer.
DC Current regulation will be better than 1%.
The controller will keep current limited at set
value under input supply variation and load current
variation to avoid excessive current to the structure.
AUTOMATIC MODE
The operation of the unit in this mode will be
fully automatic and will be controlled by the
reference electrode feedback. The unit will automatically
maintain reference voltage or pipe to soil potential
(P.S.P.) within 10mV of the set value under all
conditions. The controller will maintain the structure
protected to set PSP value under input supply
variation, load current variation and external
changes. The unit is capable of accepting up to
three reference voltages simultaneously. Reference
selector logic selects the lowest (least protected)
reference signal and maintains the protection
level. Feature is also provided to select one
out of three reference electrodes by means of
a manually operated reference selector switch.
|