Q. Do you have NABL accredited testing facility for RPD Meter?
Our RPD meter calibration lab is approved as per NABL-ISO17025
Q. Does your RPD Meter have HF/LF pulser for connecting to EVC & Flow Computer?
Our RPD meter comes with HF/LF compatible to connect with EVC or Flow computer. Please mention clear requirements at the time of raising RFQ
Q. Does your RPD meter have the provision of pressure & temperature tapping?
Yes, Pressure & temperature tapping is available on body of RPD meter.
Q. Which gloves should I select?
Insulating Rubber Gloves
For selecting gloves, find out the voltage of network/panel and select the appropriate class from the classification table provided in specifications
Q. What is the best rangeability of RPD Meters, you can provide ?
"Rangeability of RPD meter is different based on size 1. G16 to G25 - 1:50 2. G40 to G65 - 1:100 3. G100 & above: 1:160 under current practice"
Q. What is the minimum and maximum flowrange of RPD meters you have?
We offer 150# RPD Meters from 0.50 AM3/Hr to 1000 AM3/Hr
Q. Which certification do you have for RPD meters?
Our RRM model RPD meter is approved as per EN12480 standard and same is approved by Indian Weights & Measure department
Q. What is the pressure class of RPD meters?
We have RPD meters only for 150# (150 class) pressure rating
Q. Do you have 300# (300 class) RPD meter?
No we have RPD meter for 150 class only (maximum working pressure upto 19 bar)
Q. What is the maximum size /Flow of RPD meter Raychem can offer ?
RPD G650 - DN150 is the maximum size of RPD meter available wih Raychem RPG
Q. Does smart meter available in both Postpaid & Prepaid module?
AMR Postpaid Gas Meter
» Yes, Both postpaid & prepaid module available with us.
Q. Does tamper alarm facility available in smart gas meter?
AMR Postpaid Gas Meter
» Yes, tamper alarm facility is available with smart gas meter.
Q. What are the communication protocol available in smart gas meter?
AMR Postpaid Gas Meter
» RF, LoRa, GSM, NB-IoT, Sigfox
Q. Do we able to get the meter reading data on server on monthly basis?
AMR Postpaid Gas Meter
» Yes
Q. Does smart meter available in both Postpaid & Prepaid module?
AMR Prepaid Gas Meter
» Yes, Both postpaid & prepaid module available with us.
Q. Does tamper alarm facility available in smart gas meter?
AMR Prepaid Gas Meter
» Yes, tamper alarm facility is available with smart gas meter.
Q. What are the communication protocol available in smart gas meter?
AMR Prepaid Gas Meter
» RF, LoRa, GSM, NB-IoT, Sigfox
Q. Do we able to get the meter reading data on server on monthly basis?
AMR Prepaid Gas Meter
» Yes
Q. Does G1.6 mechanical gas meter is certified with EN 1359 standard?
Diaphragm Gas Meter
» Our G1.6 mechanical gas meter is certified with the latest standard of EN 1359.
Q. Does G1.6 mechanical gas meter is available with both left & right entry?
Diaphragm Gas Meter
» Yes, Our meter is available in both left & right entry.
Q. What is the accuracy of G1.6 mechanical gas meter?
Diaphragm Gas Meter
» ± 1.5% - Qmax to Qt , ± 3% - Qt to Qmin
Q. What is the flow range of G1.6 mechanical gas meter?
Diaphragm Gas Meter
» Qmax- 2.5 M³/Hr , Qmin – 0.016 M³/Hr
Q. What is the technology used for manufacturing KAMFET Electrical Insulating Gloves?
Insulating Rubber Gloves
KAMFET Electrical gloves are manufactured with latest robotic latex dipping technology
Q. Why do I need to wear leather over gloves?
Insulating Rubber Gloves
Rubber insulating gloves are designed for protecting against electrical shocks but not designed for mechanical hazards. To provide mechanical hazard protection like abrasion, cut, tear and puncture, wearing leather over gloves.
Q. How should I store my rubber gloves?
Insulating Rubber Gloves
Rubber insulating gloves should be stored hanging in a glove bag with the fingers up, not laid flat. Leather protectors should be removed before storing. Store in a dry and cool location as specified by the manufacturer in the instruction manual. Keep the gloves away from direct sunlight or areas where ozone is generated due to motors or any other possible source.
Q. Does Electrical insulation gloves need retesting?
Insulating Rubber Gloves
Yes. As per governing standards of electrical insulation gloves, the gloves need to be dielectrically retested after every six months from the date of usage. For further clarification follow the instructions provided in the instruction manual.
Q. Can you offer calibration service for RPD meters?
Yes, we can calibrate 150# RPD & Turbine meters flow ranging from 0.25 to 2500 m3/hr as per our NABL scope
Q. Does lubrication oil comes with supply of RPD meter?
Yes, We supply lubrication oil with RPD meter.